Mitsubishi Electronics E70 Benutzerhandbuch

Seite von 214
4 Connection
MITSUBISHI CNC
78
4.2.2 Connecting with Power Supply
Connect a general-purpose 24VDC stabilized power supply or PD25 power supply unit to the control unit. 
(1) When using general-purpose 24VDC stabilized power supply
(Note 1) Rush current may occur to lead welding on the contacts, when a magnetic switch such as relay directly 
controls 24VDC's ON/OFF during 24V power supply to the control unit.  Use relay with large heat 
capacity of contacts to control 24VDC's ON/OFF. 
(Note 2) Make a short-circuit between 0V and FG on the terminal to cut noise. 
<Related items>
Cable drawing "Cable: F070 Cable"
Connector pin assignment: "General Specifications: Control Unit" (DCIN connector)
(2) When using PD25 power supply unit
(Note)
ACFAIL function is not available with this NC system. (CF01 is not connected.)
<Related items>
Cable drawing: "Cable: F110 Cable", "Cable: F170 Cable"
Connector pin assignment: "General Specifications: Control Unit" (DCIN connector)
DCIN
DCIN
1
2
3
FG
0V
 
0V
+24V
AC
AC
FG
NFB
MC
MC
MC
ON
OFF
Y
DCIN
FG
L1
L2
L3
Connector name : DCIN
 
Connector
: 2-178288-3
Contact
: 1-175218-5
Recommended manufacturer: Tyco Electronics AMP
 
Control unit
F070 cable
(Note 2)
24VDC
DCIN
 
DCIN
Y
CF01
ACFAIL
ACIN
ON/OFF SW
ON/OFF
FAN ALARM
DCOUT
POWER
ON
OFF
NFB
MC
L1
FG
L2
L3
1
2
3
:
F170 cable
F110 cable
ON/OFF switch
(Note)
Control unit