Mitsubishi Electronics E70 Benutzerhandbuch

Seite von 214
4 Connection
MITSUBISHI CNC
84
(2)
When using the MDS-DJ unit together
4.2.5.2 Connecting with MDS-DJ Series
<Connection>
CN1A: CN1B connector on NC or previous stage's drive unit
CN1B: CN1A connector on next stage's drive unit
CAUTION
Connect the NC and the drive units by the optical communication cables. The distance between the NC and the 
final drive unit must be within 30m and the bending radius within 80mm.
POINT
Axis Nos. are determined by the rotary switch for setting the axis No. (Refer to the MDS-DJ Series Instruction 
Manual.) The axis No. has no relation to the order for connecting to the NC.
MDS-DM2-SPV
MDS-DJ-V1
Connected  
to the NC 
Optical 
communication 
cable 
The optical communication cables from the NC to the 
final drive unit must be within 30m. 
5th axis 
(Final axis)
Servo:2nd/3rd/4th axis
Spindle:1st axis
 
MDS-DJ-V1
MDS-DJ-SP
MDS-DJ-V1
MDS-DJ-V1
3rd axis
4th axis
1st axis
2nd axis
Connected 
to the NC
Optical 
communication 
cable
The optical communication cable up to 5m can be used in G396 series, up to 10m in G395 series, and up to 30m in G380 series.