Mitsubishi Electronics E70 Benutzerhandbuch

Seite von 214
E70 Series Connection Manual
Appendix 1.22 FCUA-R030 Cable
139
Appendix 1.22 FCUA-R030 Cable
Max. cable length:  20m
Application:  SKIP input cable
(Note)
Fold the cable shield over the sheath, and wrap copper foil tape over it. Connect the wound copper foil 
tape to GND plate of the connector. 
[SKIP]
Connector: 10120-3000VE 
Case:  10320-52F0-008 
Recommended manufacturer: 3M
Wire material: UL1061-2464 
AWG22×6P 
Recommended manufacturer: 
Oki Electric Cable
Crimp terminal: V1.25-4 ×12 
Recommended manufacturer: JST
SKIP
FG
SKIP
SKIP0
SKIP1
SKIP2
SKIP3
SKIP4
SKIP5
SKIP6
SKIP7
GND
GND
GND
GND
SKIP0
SKIP1
SKIP2
SKIP3
SKIP4
SKIP5
SKIP6
SKIP7
RG
RG
RG
RG
2
12
3
13
7
17
8
18
1
11
5
15