Baracoda 2 Benutzerhandbuch

Seite von 42
 
BaracodaPencil 2 – Communication Protocol v1.3   
- 32 - 
Data Capture 
for Workforce 
in Motion 
Example 
Example 
Example 
Example 2.2 
2.2 
2.2 
2.2   
 
 
 Setting a configuration of all symbologies.
Setting a configuration of all symbologies.
Setting a configuration of all symbologies.
Setting a configuration of all symbologies. 
 
 
 
Frame to be sent to the decoder: 
 
‘A’ 
‘B’ 
$13  
Header 
Type 
Size 
 
Command 
 
 
Reading this frame, the decoder understands: 
The user wants to set a configuration (Type "B") for all the symbologies (Header "A"). The 
configuration can only contain general options and the Size field must be equal to 1. Then, the 
Command field contains the configuration itself: 
 
 
$013 
Bit 
Option 
 
Symbology Enabled 
 
Min. length Enabled (set to 6 as default) 
 
Checksum calculation Disabled 
 
Checksum transmission Disabled 
 
Max. length Enabled (set to 32 as default) 
 
 
 
 
 
2.4.6.3.
2.4.6.3.
2.4.6.3.
2.4.6.3.
 
Usual command
Usual command
Usual command
Usual command 
 
 
 
Example 
Example 
Example 
Example 3.1 
3.1 
3.1 
3.1   
 
 
 Modifying a configuration of all symbologies.
Modifying a configuration of all symbologies.
Modifying a configuration of all symbologies.
Modifying a configuration of all symbologies. 
 
 
 
We now want disable Min length and Enable start/stop characters (for the symbologies having 
those), regardless of the other options’ settings. 
Frame to be sent to the decoder: 
 
‘A’ 
‘D’ 
‘C’ , ‘I’  
Header 
Type 
Size 
 
Command 
 
 
Reading this frame, the decoder understands: 
The user wants to send a command (Type "D") to all the symbologies (Header "A"). Any command 
can be sent but not all may be effective on all symbologies.  
The command "C" will first be sent to all symbologies, and applied to all of them since they all have 
this option available. 
Then the command "I" will also be sent to all symbologies but only some of them will apply it 
(Code39, Codabar).