Operations
Calibrate the Printer
76
P1009874-002
Xi4™/RXi4™ User Guide
1/7/10
Calibrate the Printer
Calibrate the printer when it is first put into service. Calibration allows the printer to establish 
the proper settings for the specific media and ribbon used in your application. You may 
calibrate the printer at other times as needed
 shows the different methods for 
calibration.
Important • 
To retain calibration settings in the printer’s memory when the printer is power 
cycled, you must save the changes permanently. See 
.
Table 7 • Types of Calibration
Type of Calibration
Description
When/How It Occurs
Auto-calibration 
The printer automatically sets the value 
it detects for the spaces between labels.
Occurs at the following times:
• When the printer is first turned on if 
CALIBRATION is selected for 
MEDIA
 
POWER
 
UP
 (see 
• When the printer feeds media after 
the printhead is closed if 
CALIBRATION is selected for 
HEAD CLOSE
• As part of both the sensor profile and 
media and ribbon sensor calibration 
procedures.
Long Calibration 
The printer does the following:
• feeds media and ribbon
• sets the values it detects for media 
length, media type (continuous or 
non-continuous), and print mode 
(thermal transfer or direct thermal)
• updates the sensor values
To perform a long calibration, do one of 
the following:
• Press 
PAUSE
 on the control panel to 
pause the printer, and then press 
CALIBRATE
.
• Select CALIBRATION for the 
MEDIA
 
POWER
 
UP
 or 
HEAD
 
CLOSE
 parameter (see 
 or 
Short Calibration
The printer calibrates using the current 
sensor values rather than detecting the 
spaces between labels and resetting the 
sensors. This calibration sequence uses 
fewer labels than the long calibration 
sequence, but it is less reliable because 
the values that are stored in the sensors 
could be incorrect.
Select SHORT CAL for the 
MEDIA
 
POWER
 
UP
 or 
HEAD
 
CLOSE
 parameter 
 or