Zebra Technologies 11680100201 Benutzerhandbuch

Seite von 190
91
Configuration
Standard Control Panel Parameters
1/7/10
Xi4™/RXi4™ User Guide
P1009874-002
Standard Control Panel Parameters
 shows parameters in the order in which they are displayed when you press 
NEXT/SAVE
 after entering Setup mode. For parameters that do not appear in this table, see 
.
Note • 
Your label preparation software or the printer driver may override adjustments made 
through the control panel. Refer to the software or driver documentation for more 
information.
Table 8 • Printer Parameters (Sheet 1 of 22)
Language/Parameter
Action/Explanation
Adjust Print Darkness
Darkness (burn duration) settings depend on a variety of factors, including 
ribbon type, media type, and the condition of the printhead. You may adjust 
the darkness for consistent high-quality printing.
Important • 
Set the darkness to the lowest setting that provides 
good print quality. If the darkness is set too high, the ink may 
smear, the ribbon may burn through, or the printhead may wear 
prematurely.
If printing is too light or if there are voids in printed areas, increase the 
darkness. If printing is too dark or if there is spreading or bleeding of 
printed areas, decrease the darkness.
 can be used to determine the best darkness 
setting. You may want to adjust darkness while performing the 
. Because the darkness setting takes effect immediately, 
you can see the results on labels that are currently printing. Darkness 
settings also may be changed by the driver or software settings.
Default Value: +4.0
Range: 0 to +30.0
To change the value shown:
1.
Press 
PLUS (+) 
to increase darkness.
2.
Press 
MINUS (-)
 to decrease darkness.
Adjust Print Speed
Adjusts the speed for printing a label (given in inches per second). Slower 
print speeds typically yield better print quality. Print speed changes take 
effect upon exiting Setup mode.
Default Value: 2 IPS
Range: Varies by printer type (see 
 for values by model)
To change the value shown:
1.
Press 
PLUS (+) 
to increase the value.
2.
Press 
MINUS (-)
 to decrease the value.