Troubleshooting
Troubleshooting When There is Error Display
108
3.2.2  Fan problem
†
The following condition is handled as a fan problem:
„
During operation of the Cooling Fan Motor, the lock signal (H or L) has been 
maintained for more than the predetermined period of time.
3.2.3  Polygon Motor Error
†
Any of the following conditions is handled as an polygon motor error:
„
The lock signal was not detected within the predetermined period of time 
counted from one second after start of the polygon motor.
„
The lock signal was not detected during the period of 1 second counted from 
1.5 seconds after emission of the first lock signal.
„
No lock signal was detected for 0.5 second continuously under the conditions 
where the polygon motor was in a steady running state.
„
The lock signal was kept ON for more than 5 seconds even with the polygon 
motor turned OFF.
Table 3-5. Troubleshooting for “Fan problem”
Step
Action and Question
Yes
No
Parts below can be the source of this error (
1
Cooling Fan Motor 1
Check the connection of the motor connector, and 
correct it if any problem is found.
♦Has the error been cleared?
Problem 
solved
Go to Step 2
2
Cooling Fan Motor 2
Check the loading on the fan mechanism, and correct 
it if any problem is found.
♦Has the error been cleared?
Problem 
solved
Go to Step 3
3
Cooling Fan Motor 3
Replace the cooling fan.
♦Has the error been cleared?
Replace the 
cooling fan.
Go to Step 4
4
Main Board Assy.
Replace the Main Board Assy.
♦Has the error been cleared?
Replace the 
Main Board 
Assy.
Go to 
Table 3-6. Troubleshooting forTroubleshooting for “Polygon Motor Error”
Step
Action and Question
Yes
No
Parts below can be the source of this error (
• FFC
1
Connection with connectors
Check the connection of the cable, and correct it if 
any problem is found.
♦Has the error been cleared?
Problem 
solved
Go to Step 2
2
PH unit
Replace the PH unit.
♦Has the error been cleared?
Replace the 
PH unit.
Go to Step 3
3
Main Board Assy.
Replace the Main Board Assy.
♦Has the error been cleared?
Replace the 
Main Board 
Assy.