 Troubleshooting
Checking High Voltage - 14
 
Checking High Voltage
 
±
 
Warning:
 
  Read all of the warnings, notes, and steps of this 
procedure before beginning.
 
±
 
Warning:
 
  Voltage at the anode, with the power on, can cause 
serious injury. Doublecheck all multimeter connections before 
taking the reading.
 
±
 
Warning:
 
  Probe the anode carefully. Serious damage and 
injury may occur if the anode is knocked off while the CRT is 
charged.
 
Note:
 
  Do not attempt this procedure without the Apple high- 
voltage probe. Use only the Apple high-voltage probe. Other high-
voltage probes will not give accurate readings for this procedure.