Sharp PNA601 Benutzerhandbuch

Seite von 60
E
37
SCREEN menu
Function
Command Direction
Parameter
Reply
Control/Response contents
*1
*2
(A) (B)
AUTO
ASNC
W
1
When the input mode is PC D-SUB, PC RGB.
-
○ ○
CLOCK
CLCK
WR
0-1200
0-1200 When the input mode is PC D-SUB, PC RGB.
Varies depending on the signal.
PHASE
PHSE
WR
0-63
0-63 When the input mode is PC D-SUB, PC RGB.
POSITIONING
POSITION OF
THE LONGEST
DIRECTION
HPOS
WR
0-100
0-100 0-800 on PC D-SUB, PC RGB.
Varies depending on the signal.
POSITION OF
THE SHORTEST
DIRECTION
VPOS
WR
0-100
0-100 0-200 on PC D-SUB, PC RGB.
Varies depending on the signal.
SIZE
POSITION OF
THE LONGEST
DIRECTION
HSIZ
WR
0-100
0-100
POSITION OF
THE SHORTEST
DIRECTION
VSIZ
WR
0-100
0-100
RESOLUTION
LONGEST
DIRECTION
RESOLUTION
HRES
WR
300-1920
300-1920 When the input mode is PC D-SUB, PC RGB.
Only even numbers are valid for parameters. 
Varies depending on the signal.
SHORTEST
DIRECTION
RESOLUTION
VRES
WR
200-1200
200-1200
RESET
ARST
W
1
Controlling the Monitor with a PC (RS-232C)