AU OPTRONICS CORPORATION 
Product Specification 
document version 1.0                                                                                                                                                                                                    7 
NUMPAGES |29}
M240HW01 V2
Note 1: Measurement method 
The LCD module should be stabilized at given temperature for 30 minutes to avoid abrupt 
temperature change during measuring (at surface 35 )
. In order to stabilize the luminance, the 
measurement should be executed after lighting Backlight for 30 minutes in a stable, windless and 
dark room.     
 
 
 
 
 
 
 
 
 
 
 
 
 
Note 2:
 Definition of viewing angle 
measured by ELDIM (EZContrast 88) 
Viewing angle is the measurement of contrast ratio ≧10, at the screen center, over a 180° 
horizontal and 180° vertical range (off-normal viewing angles). The 180° viewing angle range is 
broken down as follows; 90° (θ) horizontal left and right and 90° (Φ) vertical, high (up) and low 
(down). The measurement direction is typically perpendicular to the display surface with the 
screen rotated about its center to develop the desired measurement viewing angle. 
 
 
 
 
 
 
 
 
 
 
 
 
Center of the screen 
TFT-LCD Module
Measured distance 
Photo detector 
LCD Panel