Acer D240H Benutzerhandbuch

Seite von 79
 
 
 
 
 
AU OPTRONICS CORPORATION 
Product Specification 
document version 1.0                                                                                                                                                                                                    11 
NUMPAGES |29}
M240HW01 V2
4.0 Absolute Maximum Ratings   
Absolute maximum ratings of the module are as following: 
4.1 TFT LCD Module 
                                                 
 
 
 
 
4.2 Backlight Unit 
                                                 
 
Item Symbol 
Min 
Max 
Unit 
Conditions 
CCFL Current 
ICFL 
3.0 8.0 
[mA] rms 
Note 1,2 
 
 
4.3 Absolute Ratings of Environment 
 
Item 
Symbol 
Min. 
Max. 
Unit 
Conditions 
Operating Temperature 
TOP 
+50 
[
o
C] 
Operation Humidity 
HOP 
90 
  [%RH] 
Storage Temperature   
TST 
-20 
+60 
[
o
C] 
Storage Humidity 
HST 
5 90 
[%RH] 
Note 3 
Note 1:
 With in Ta (25℃) 
Note 2: 
Permanent damage to the device may occur if exceeding maximum values 
Note 3: 
For quality perfermance, please refer to AUO IIS(Incoming Inspection Standard). 
 
Operating Range     
                   
Storage Range     
 
Item Symbol 
Min 
Max 
Unit 
Conditions 
Logic/LCD Drive 
Voltage 
VDD 0  6.0 [Volt] 
Note 1,2