3M M2256PW Benutzerhandbuch

Seite von 41
36 
 
3M™ Multi-touch Display M2256PW User Guide 
3M Touch Systems, Inc. Proprietary Information – 37531 Rev D
Description:
This is the default mode of operation at power up. Touch reports include 
touchdown and liftoff events as well as continuing touches. 
Name Command 
Syntax:
<SOH>NM<CR> 
Response:
<SOH>0<CR> Positive response. 
Description:
Returns a name string  
Null Command 
Syntax:
<SOH>Z<CR> 
Response:
<SOH>0<CR> Positive response. 
Description:
Queries the controller and waits for a response. 
Use Z to determine that you are communicating with the controller or to make sure that a 
utility is communicating with the controller. Using this command does not affect the 
controller’s current operating parameters. 
Output Identity 
Syntax:
<SOH>OI<CR> 
Response:
<SOH>ADXxxx<CR> 
where: 
AD 
=  Two ASCII characters that describe the type of 3M Touch Systems controller.
Xxxx  =  This is a unique identifier not necessarily the actual firmware revision 
number. 
Description:
Returns a 6-character identifier, which describes the controller type and the firmware 
version number. . 
Soft Reset 
Syntax:
<SOH>R<CR> 
Response:
<SOH>0<CR> Positive response
Description:
Initializes the hardware and the firmware, causes the controller to stop sending data, and 
recalculates the environmental conditions (for example, stray and offset values). The 
Reset command also cancels the Calibrate command and returns the controller to normal 
operation.