Maintenance
Checking HDD status (Maintenance)
The operations of the installed HDD can be checked 
on the screen which appears when the maintenance 
button on the SETTING screen is pressed.
The inserted HDD is easily damaged.
To keep the unit in optimal condition, we recommend 
that you inspect it regularly and confirm the state of the 
HDD in advance.
B
C
D
A
1
  Select the HDD to check.
 Press the Start Test button.
    The display changes to [STOP].
The data on the entire HDD is read, and if it is taking 
longer to access the data than the prescribed access 
time, a warning message is displayed.
To stop the checking operation at any time, press the 
STOP button.  The check operation is stopped, and the 
results of what has been checked so far are displayed.
 •  It takes about 2 hours to check 500 GB of data so 
use the external DC power supply.
 •  Only HDD1 is accessed when the unit is used in the 
RAID1 mode.  To check both HDDs, set the RAID1 
mode to the JBOD mode, and check each HDD in 
turn.
 Select
Select HDD on which to perform maintenance.
  Maintenance status
   ● Max. Time
     Display maximum access time (ms).
   ● Min. Time
     Display minimum access time (ms).
   ● Averg. Time
     Display average access time (ms).
   ● Speed
     Display average access rate (MB/s).
   ● Error Count
     Display average number of errors detected.
   ● HDD Status
     Display HDD status.
If “WARNING” or “NG” is displayed, remove the 
HDD immediately.
  START TEST button
Start HDD status verification.
 CLOSE button
Return to the main screen.