 SCSI Description
5-22
Maxtor Atlas 10K III
Note:
Vendor Information, Product Identification, and Product Revi-
sion Level are returned as shown in Table 5-22.
ACKQREQQ
0
Device supports REQ and ACK data handshake on Q cable.
Addr32
0
32-bit wide SCSI address
Addr16
0/1
16-bit wide SCSI address
TrmTSK
0
TERMINATE TASK Function is not supported
Response Data For-
mat
2
This Standard Inquiry Data is in the format specified in the International 
Standard.
RelAdr
0
Relative Addressing is not supported.
WBus 32
0
32-bit wide bus is not supported.
WBus 16
0 or 1
The WBus bit is 1 if the drive supports 16-bit data transfer. The bit is 0 
if the drive only supports 8-bit transfer.
Sync
1
The drive supports Synchronous Data Transfers.
Linked
1
Linked Commands are supported.
TransDis 1
Indicates that the drive supports CONTINUE TASK and TARGET 
TRANSFER DISABLE messages.
CmdQue
1
The drive supports Tagged Command Queuing
SftRe 0
The drive implements the hard reset option in response to assertion of 
the SCSI Bus reset line.
VS
0
Vendor Specific
Product 
Identification
The 
value in 
this field 
is:
ATLAS10K3_18_WLS, ATLAS10K3_36_WLS, ATLAS10K3_73_WLS
ATLAS10K3_18_SCA, ATLAS10K3_36_SCA, ATLAS10K3_73_SCA
Clocking 11
The contents of this field define the setting of the double-edge clocking 
option (See Chapter 6). Note that the clocking field does not apply to 
asynchronous transfers of data. Options available are: 
%'" 
00b 
01b 
10b 
11b
"($)* )%+
Indicates the device server supports only Single 
Transition (ST)
Indicsates the device server supports only Double 
Transition (DT)
Reserved
Indicates the device server supports ST and DT
QAS 
(U160)
Quick Arbritrate Support. If the value of this field is 1, it indicates that 
the device server supports the quick arbitrate feature. A value of 0 in-
dicates that the device server does not support this feature. 0 is default 
setting.
IUS 
(U320)
Information Unit Supported. If the value of this field is 1, it indicates 
that the device server supports information units. A value of 0 indicates 
that the device server does not support information units. Default is 0.
&*2,9
<2
"()**+