Sun Microsystems 6900 Series Benutzerhandbuch

Seite von 162
106
Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002
Sun StorEdge T3+ Array Storage Service Processor
Verification
1. Run
port listmap
on the Sun StorEdge T3+ array to see the failover event.
2. Compare the virtualization engine configuration to a saved configuration by
running
/opt/SUNWsecfg/runsecfg
and choosing Verify Virtualization Engine
Map.
The output is from the
diff
(1) command, which shows the lines that have been
added, changed, or deleted. Notice that the active Sun StorEdge T3+ array controller
WWN has changed for one of the Sun StorEdge T3+ arrays, indicating it is using its
alternate path.
FIGURE 8-3
Manage Configuration Files Menu
t3b0:/:<1>port listmap
port   targetid   addr_type   lun   volume        owner   access
u1p1      0        hard        0    vol1          u1      primary
u1p1      0        hard        1    vol2          u1      failover
u2p1      1        hard        0    vol1          u1      failover
u2p1      1        hard        1    vol2          u1      primary
 MANAGE CONFIGURATION FILES MENU
1) Display Virtualization Engine Map
2) Save Virtualization Engine Map
3) Verify Virtualization Engine Map
4) Help
5) Return
Select configuration option above:> 3
Verifying Virtualization Engine map for v1........
ERROR: virtualization engine map for v1 has changed.
18c18
< t3b01      5     T49153   116.7     0.7     50020F230000725B       1
> t3b01      5     T49153   116.7     0.7     50020F2300006DFA       1
28c28
< t3b01      T49153   50020F230000725B  60020F2000006DFA
> t3b01      T49153   50020F2300006DFA  60020F2000006DFA
37c37
< I00002     2900006022004186  v1b      Yes     08.14              0
> I00002     2900006022004186  Unknown  No      Unknown            0
46d45
< Undefined        210000E08B026C0F  I00002     Yes            0
 checkvemap: virtualization engine map v1 verification complete: FAIL.