Sun Microsystems 6900 Series Benutzerhandbuch

Seite von 162
Chapter 8
Troubleshooting the Sun StorEdge T3+ Array Devices
121
For Internal Use Only
t3
volume
StateChange-
Red
Y
[ Info/Action ]
Information: The Sun
StorEdge T3+ array
has reported that a
power cooling unit
has been disabled.
Recommended action:
1. Check the Sun
StorEdge T3+ array
syslog for battery
hold times.
2. If < 6 minutes,
replace the battery,
or the entire PCU,
as required.
t3
power
StateChange-
Red
Y
[ Info/Action ]
power.u1pcu2
(
TECT
ROL-CAN.300-
1454-
01(50).008275
) in
T3 rasd2-t3b
1
(ip=xxx
.0.0.41
) is
now Not-Available
(status-state changed
from ready-enabled to
ready-disable).
Information: The Sun
StorEdge T3+ array
has reported that a
LUN has changed
state.
Recommended action:
1. Telnet to the
affected Sun
StorEdge T3+ array
2. Check the status of
LUNs via
vol
mode
or
vol
stat
.
t3
enclosure
Statistics
Statistics about
T3
d2-t3b1
(ip=xxx.
0.0.41
)
Category
Component
EventType
Sev
Action
Description
Information