Sun Microsystems 6900 Series Benutzerhandbuch

Seite von 162
Chapter 2
General Troubleshooting Procedures
7
For Internal Use Only
Multipathing Options in the Sun
StorEdge 6900 Series
Using the virtualization engines presents several challenges in how multipathing is
handled in the Sun StorEdge 6900 series.
Unlike Sun StorEdge T3+ array and Sun StorEdge network FC switch-8 and switch-
16 switch installations, which present primary and secondary pathing options, the
virtualization engines present only primary pathing options to the data host. The
virtualization engines handle all failover and failback operations and mask those
operations from the multipathing software on the data host.
The following example illustrates a Sun StorEdge Traffic Manager problem on a Sun
StorEdge 6900 series system.
luxadm display
/dev/rdsk/c6t29000060220041F96257354230303052d0s2
DEVICE PROPERTIES for disk: /dev/rdsk/
c6t29000060220041F96257354230303052d0s2
  Status(Port A):       O.K.
  Status(Port B):       O.K.
  Vendor:               SUN
  Product ID:           SESS01
  WWN(Node):            2a000060220041f4
  WWN(Port A):          2b000060220041f4
  WWN(Port B):          2b000060220041f9
  Revision:             080C
  Serial Num:           Unsupported
  Unformatted capacity: 102400.000 MBytes
  Write Cache:          Enabled
  Read Cache:           Enabled
    Minimum prefetch:   0x0
    Maximum prefetch:   0x0
  Device Type:          Disk device
  Path(s):
  /dev/rdsk/c6t29000060220041F96257354230303052d0s2
  /devices/scsi_vhci/ssd@g29000060220041f96257354230303052:c,raw
   Controller           /devices/pci@6,4000/SUNW,qlc@2/fp@0,0
     Device Address     2b000060220041f4,0
     Class              primary
     State              ONLINE
   Controller           /devices/pci@6,4000/SUNW,qlc@3/fp@0,0
     Device Address     2b000060220041f9,0
 Class              primary
     State              ONLINE