Sun Microsystems 6900 Series Benutzerhandbuch

Seite von 162
40
Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002
A4/B4 Fibre Channel (FC) Link
If a problem occurs with the A4/B4 FC link:
In a Sun StorEdge 3900 series system, the Sun StorEdge T3+ array will fail over.
In a Sun StorEdge 6900 series system, no Sun StorEdge T3+ array will fail over,
but a severe problem can cause a path to go offline.
are examples of A4/B4 Link Notification Events.
FIGURE 3-9
A4/B4 FC Link Data Host Notification
Site     : FSDE LAB Broomfield CO
Source   : diag.xxxxx.xxx.com
Severity : Warning
Category : Message
DeviceId : message:diag.xxxxx.xxx.com
EventType: LogEvent.driver.MPXIO_offline
EventTime: 01/29/2002 14:28:06
Found 2 ’driver.MPXIO_offline’ warning(s) in logfile: /var/adm/messages on
diag.xxxxx.xxx.com (id=80e4aa60):
<snip>
----------------------------------------------------------------------
Site     : FSDE LAB Broomfield CO
Source   : diag.xxxxx.xxx.com
Severity : Warning
Category : Message
DeviceId : message:diag.xxxxx.xxx.com
EventType: LogEvent.driver.Fabric_Warning
EventTime: 01/29/2002 14:28:06
Found 1 ’driver.Fabric_Warning’ warning(s) in logfile: /var/adm/messages on
diag.xxxxx.xxx.com (id=80e4aa60):
INFORMATION:
  Fabric warning
<snip>
status of hba /devices/pci@a,2000/pci@2/SUNW,qlc@5/fp@0,0:devctl on
diag.xxxxx.xxx.com changed from CONNECTED to NOT CONNECTED
INFORMATION:
  monitors changes in the output of luxadm -e port
  Found path to 20 HBA ports
  /devices/sbus@2,0/SUNW,socal@d,10000:0   NOT CONNECTED