Hitachi HCS721016CLA382 Benutzerhandbuch

Seite von 258
Hitachi hard disk drive specifications   
249 
11.57  Write Stream PIO (3Bh) 
 
Command Block Output Registers
 
 
Command Block Input Registers
 
Register
 
7
 
6
 
5
 
4
 
3
 
2
 
1
 
0
 
 
Register
 
7
 
6
 
5
 
4
 
3
 
2
 
1
 
0
 
Data Low
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
 
Data Low
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
Data High
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
 
Data High
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
Feature
 
Current
 
V
 
V
 
V
 
V
 
-
 
V
 
V
 
V
 
 
Error
 
...See Below...
 
Previous
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
   
 
Sector Count
 
Current
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
 
Sector Count
 
HOB=0
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
Previous
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
 
HOB=1
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
Sector 
Number
 
Current
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
 
Sector 
Number
 
HOB=0
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
Previous
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
 
HOB=1
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
Cylinder Low
 
Current
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
 
Cylinder Low
 
HOB=0
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
Previous
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
 
HOB=1
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
Cylinder High
 
Current
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
 
Cylinder High
 
HOB=0
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
Previous
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
 
HOB=1
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
Device/Head
 
1
 
1
 
1
 
D
 
-
 
-
 
-
 
-
 
 
Device/Head
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
Command
 
0
 
0
 
1
 
1
 
1
 
0
 
1
 
1
 
 
Status
 
...See Below...
 
 
Error Register
 
 
Status Register
 
7
 
6
 
5
 
4
 
3
 
2
 
1
 
0
 
 
7
 
6
 
5
 
4
 
3
 
2
 
1
 
0
 
CRC
 
UNC
 
0
 
IDN
 
0
 
ABT
 
T0N
 
CCTO
 
 
BSY
 
RDY
 
SE
 
DWE
 
DRQ
 
COR
 
IDX
 
ERR
 
V
 
0
 
0
 
V
 
0
 
V
 
0
 
V
 
 
0
 
V
 
V
 
0
 
-
 
0
 
-
 
V
 
Table 178    Write Stream PIO Command (3Bh) 
 
This command writes from 1 to 65536 sectors as specified in the Sector Count register.    A sector count of 0 
requests 65536 sectors. 
If the Write Continuous bit is set to one, the device shall not stop execution of the command due to errors.    If 
the WC bit is set to one and errors occur in the transfer or writing of the data, the device shall continue to transfer 
the amount of data requested and then provide ending status with the BSY bit cleared to zero, the SE bit set to 
one, the ERR bit cleared to zero, and the type of error, IDNF, or ABRT, reported in the error log.    If the WC bit is 
set to one and the Command Completion Time Limit expires, the device shall stop execution of the command 
and provide ending status with BSY bit cleared to zero, the SE bit set to one, the ERR bit cleared to zero, and 
report the fact that the Command Completion Time Limit expired by setting the CCTO bit in the error log to one,   
In all cases, the device shall attempt to transfer the amount of data requested within the Command Completion 
Time Limit event if some data transferred is in error.