Adaptec 48300 Benutzerhandbuch

Seite von 88
Appendix D: Using the AFU for DOS
76
5
If you have multiple HostRAID controllers only—At the DOS prompt, type 
afu list,
 
then press Enter.
This command displays the Adaptec SAS HostRAID controllers in your system. Note the 
HostRAID controller number for the controller you want to update; you may need it in 
Step 6 to perform the update.
6
You can update the flash using any of the following alternatives: 
a
Updating the Flash on a Single HostRAID Controller—To flash the firmware on a 
single HostRAID controller, type:
afu update /C <controller_number>
Where 
controller_number
 is the number of the controller whose firmware you are 
updating. For example, to upgrade Controller 0, type:
afu update /C 0
b
Updating the Flash on Multiple Controllers—To flash the firmware on multiple 
HostRAID controllers, type:
afu update /C <controller_number_a>,<controller_number_b>
Where 
<controller_number_a>
 and 
<controller_number_b>
 are the number of one 
of the Adaptec HostRAID controllers whose firmware you are updating.
To upgrade HostRAID controllers 0, 2, and 3 for example, type:
afu update /C 0, 2, 3
c
Updating the Flash on All HostRAID Controllers Simultaneously—To flash the 
firmware on all HostRAID controllers, type:
afu update /C all
Note: 
The UFI file identifies the appropriate HostRAID controllers, so you do not 
have to worry about flashing the wrong controller.
7
The AFU prompts you to put in the first firmware disk. 
When it detects that the disk is in the drive, the AFU reads the part of the firmware image 
contained on the first disk.
8
When prompted, remove the first firmware disk and insert the second firmware disk. 
9
If necessary, repeat 
 until the process is complete.