Xerox 144 Benutzerhandbuch

Seite von 63
Xerox Nuvera
®
 100/120/144 EA Digital Production System - Customer Expectations Document
 
- 14 -
 
Product Space & Power Requirements 
Item 
Xerox Nuvera
®
 100/120/144 EA 
Digital Production System 
Comments 
Size – Printer w/ 1 SFM 
/ Scanner & MFF 
132”  (W) X 29 ” (D) X 61.6 ” (H) 
3353 mm x 737 mm x 1565 mm  
 
Size – Printer w/ 1 SFM 
& SEM / FTM 
125”  (W) X 29 ” (D) X 61.6 ” (H) 
3175 mm x 737 mm x 1565 mm  
Printer Digital Tower 61.6” (1565 mm) (Height)  
DFA finishing devices vary by device*. 
Size – Printer w/ 1 SFM 
& SEM / BFM 
124”  (W) X 29 ” (D) X 61.6 ” (H) 
3150 mm x 737 mm x 1565 mm  
 
Width of additional 
SFM 
31.7”, 805mm 
Optional 
Width of BFM Plus 
49”, 1233mm 
 
Optional, BFM Plus and Interface Module used with BFM (with top 
tray) in dual BFM installations. 
Service Space 
(MFF Config.) 
Fixed:  163” (W) x 112” (D) 
            ( 4140mm x 2839mm) 
Moveable: 163” (W) x 92” (D) 
            ( 4140mm x 2336.8mm) 
- Fixed (stationary) installation: rear of the system should be at least 
30” from the wall, machine, or rear obstruction..  
- Moveable installation: rear of the system should be at least 10” from 
the wall and must be on mobility plates OR hard surface floor AND 
with no more than 4 modules including MFF and MFF Interface 
Module. 
Service Space 
(BFM / FTM Config. 
with SEM) 
BFM: 145” (W) x 112” (D) 
     3683mm x 2839 mm 
FTM: 143” (W) x 112” (D) 
     3632mm x 2839 mm 
At least 30” from the wall in rear. 
DFA finishing will increase width - FTM config. dimensions do not 
include DFA Finisher(s) dimensions or service space. 
Weight  
(MFF Config. w/ 
scanner) 
1,753 lb. (795.2 kg) 
Additional SFM – 423 lbs. (192 kg) 
With consumables loaded, except media 
Weight  
(BFM / FTM Config. 
with SEM) 
BFM: 1763 lb. (800 kg) 
FTM: 1713 lb. (777 kg) 
Additional SFM – 423 lbs. (192 kg) 
With consumables loaded, except media  
FTM config. listing does not include DFA Finisher(s) weight. 
Power Requirements 
North America / Japan  
(MFF / BFM Finishing) 
187 – 240 Volts AC (Nominal), 50 Amp , 
50/60 Hz wall service 
 
Note – FTM and DFA finishers will require 
additional power 
• UL & cUL compliant 
• Complies with the FEMP (Federal Energy Management Program) 
via the machine circuit breaker (CB); with the CB switched off, the 
system consumes less than 1 watt. 
• Energy Star (eStar) compliant** 
• Environmental Choice (Canada)** 
• 
Complies with Section 508 of the ADA Rehabilitation Act
 
Power Requirements 
Europe / FX-IBG 
187 – 240 Volts AC (Nominal), 30 Amp + 
20 Amp (2) , 50/60 Hz wall service 
 
Feeders and Finisher modules (BFMs) will 
need additional 187 – 240 VAC (Nominal), 
20 Amp, 50/60 Hz wall service 
 
Note – FTM and DFA finishers will require 
additional power 
• Units are compliant with applicable EU directives and are CE 
marked 
* - Please refer to supported inline DFA finishing devices Solution Planning Guides for Product Space and 
Power Requirements. 
** - the following configuration is not Energy Star compliant: 
•  100 ppm printer-only configuration with a BFM