Cisco Systems 15454M6DC Benutzerhandbuch

Seite von 458
9-33
Cisco ONS 15454 Installation and Operations Guide
November 2001
Chapter 9      Ethernet Operation
Remote Monitoring Specification Alarm Thresholds
Figure 9-26 Creating RMON thresholds 
Step 4
From the Slot menu, choose the appropriate Ethernet card.
Step 5
From the Port menu, choose the Port on the Ethernet card.
Step 6
From the Variable menu, choose the variable. 
 lists and defines the Ethernet Threshold 
Variables available in this field.
Step 7
From Alarm Type, indicate whether the event will be triggered by the rising threshold, falling threshold, 
or both the rising and falling thresholds.
Step 8
From the Sample Type pull-down menu, choose either Relative or AbsoluteRelative restricts the 
threshold to use the number of occurrences in the user-set sample period. Absolute sets the threshold to 
use the total number of occurrences, regardless of any time period.
Step 9
Type in an appropriate number of seconds for the Sample Period.
Step 10
Type in the appropriate number of occurrences for the Rising Threshold. 
Note
For a rising type of alarm to fire, the measured value must shoot from below the falling 
threshold to above the rising threshold. For example, if a network is running below a falling 
threshold of 400 collisions every 15 seconds and a problem causes 1001 collisions in 15 
seconds, these occurrences fire an alarm. 
Step 11
Type in the appropriate number of occurrences for the Falling Threshold. In most cases a falling 
threshold is set lower than the rising threshold. 
A falling threshold is the counterpart to a rising threshold. When the number of occurrences is above the 
rising threshold and then drops below a falling threshold, it resets the rising threshold. For example, 
when the network problem that caused 1001 collisions in 15 minutes subsides and creates only 799 
collisions in 15 minutes, occurrences fall below a falling threshold of 800 collisions. This resets the 
rising threshold so that if network collisions again spike over a 1000 per 15 minute period, an event again 
triggers when the rising threshold is crossed. An event is triggered only the first time a rising threshold 
is exceeded (otherwise a single network problem might cause a rising threshold to be exceeded multiple 
times and cause a flood of events). 
Step 12
Click the OK button to complete the procedure.