Data Capture 
for Workforce 
in Motion 
1.6/ The different connection methods 
There are two (2) different way to create a connection from a Host and a scanner: 
-
 
Slave mode (by default) 
The Host (PC, BaracodaManager, …) is creating the connection onto the scanner. 
-
 
Master mode 
The  scanner  is  creating  itself  a  connection  to  the  recorded  Host  Bluetooth  address.  This  connection 
attempt is set after a scan of barcode. The configuration of Host address (on which the scanner will set 
up a connection) can be done: 
o
 
Via BaracodaManager software. 
o
 
Via scan of barcodes. 
All  usage  mode  (Real  Time,  No  Data  Loss,  Batch)  are  obviously  available  on  those  two  different  ways  of 
connection. 
\ V T \ V T Z \ N U L \ S O H \ S O H \ F F \ F F
Enable master mode
   
 
\ V T \ V T Z \ N U L \ S O H \ N U L \ F F \ F F
Disable master mode
 
 
\ V T \ V T Z \ N U L \ S T X \ S O H \ S O H \ F F \ F F
Enable master mode and disconnect
   
 
\ V T \ V T Z \ N U L \ S T X \ N U L \ S O H \ F F \ F F
Disable master mode and disconnect
 
The configuration of the Host Bluetooth address (BDA) is made by scanning the 0-9, a-f, A-F labels (Appendix 1) 
as on a calculator; following the timestamp format shown above. 
For example: to set the following BDA: 00:c3:EF:44:a2:B9, the user will scan: 
- “Set Remote BDA” label, 
- “0” label, 
- “0” label, 
- “c” label, 
- “3” label, 
- “E” label, 
- “F” label, 
- “4” label, 
- “4” label, 
- “a” label, 
- “2” label, 
- “B” label, 
- “9” label, 
- “End of Config” label. 
 
\ V T \ V T ^ \ N U L \ S O H \ E N Q \ L F \ L F
Set Remote BDA
   
 
\
L
F
\
L
F
E
N
D
\
F
F
\
F
F
End of Config