Nvidia 680I LT SLI Benutzerhandbuch
Mainboard nForce 680i SLI/
Mainboard nForce 680i LT SLI
64
Rebuilding a RAID Mirrored Array
This section will illustrate how to replace a failed drive with a new one, and rebuild the array
to restore lost data on the newly installed drive. Rebuilding only applies to fault-tolerant
arrays which are RAID 1, RAID 0+1, and RAID 5 arrays.
to restore lost data on the newly installed drive. Rebuilding only applies to fault-tolerant
arrays which are RAID 1, RAID 0+1, and RAID 5 arrays.
1. Before rebuilding an array, you must connect new hard disk(s) onto your computer.
2. Power on your computer. When the system boots up during the POST (Power-On Self
Test), you will be given an opportunity to enter the NVIDIA RAID Setup Utility when the
screen prompts you with the following message.
screen prompts you with the following message.
“Press <F10> to enter RAID setup utility…”
3. Press
<F10> key to enter the NVIDIA RAID Setup Utility (note that you will only have a
short window of time to press <F10> before the system continues the next step of the boot
process).
process).
4. Go to the screen shown as below. Press <Enter>.