Nvidia ST380023AS Benutzerhandbuch

Seite von 22
 
 
 
 
 
Chapter 3 
____________________________________________________________________________________________________________ 
 
Rebuilding a Mirrored RAID HDD 
 
NOTE: When one of the RAID HDD fails, Windows Vista may not show a change of 
status in Disk Management in Administrative Tools. 
 
Below are the steps to rebuild the RAID storage solution. 
 
1. Press F10 during boot up to access the RAID utility.  
2. Identify the defective/degraded drive.  The utility should only list the good drive.  
    Once you replace the defective HDD, the RAID utility will mark both drives degraded. 
3. If the drive is defective, turn off the computer and replace it with one of identical size. 
4. Access the RAID utility again. 
5. Make sure the drive that is good is marked as bootable YES. 
6. Select the HDD that is defective. 
7. Delete the RAID Array. 
8. Select the HDD that you wish to make bootable. 
9. Select "(R) Rebuild" to Rebuild the RAID Array. 
10. Select Add 
11. Exit the RAID Utility Screen. 
 
 
23