Motorola MVME1X7P Benutzerhandbuch

Seite von 316
Functional Description
http://www.motorola.com/computer/literature
4-7
4
4. Notify the local MPU via interrupt if so enabled. 
Triple (or Greater) Bit Error (Cycle Type = Non-Burst Write)
Some of these errors are detected correctly and are handled the same as a 
double-bit error. The rest may show up as "no error" or "single-bit error", 
both of which are incorrect. 
Single Bit Error (Cycle Type = Scrub)
1. Write corrected data to the DRAM. 
2. Log the error if not already logged. 
3. Notify the local MPU via interrupt if so enabled. 
Double Bit Error (Cycle Type = Scrub)
1. Do not perform the write portion of the cycle. (This causes the 
location to continue to indicate a non-correctable error when 
accessed.) 
2. Log the error if not already logged. 
3. Notify the local MPU via interrupt if so enabled. 
Triple (or Greater) Bit Error (Cycle Type = Scrub)
Some of these errors are detected correctly and are treated the same as a 
double-bit error. The rest may show up as "no error" or "single-bit error", 
both of which are incorrect.