Figure 5.1:  Spectra Zone Programming
5.5
ZONE DEFINITIONS
As demonstrated in Figure 5.1, sections [001] to [016] represent zones 1 through 16 respectively, where the first
digit in each of these sections represents the zone's definition. Also, refer to Zone Speed on page 25. To disable a
zone
, clear the contents of the section corresponding to the desired zone by pressing the [
FORCE
] key 3 times and
pressing [
ENTER
]. There are 9 available Zone Definitions, which are described as follows.
5.5.1
E
NTRY
 D
ELAY
 1 
Sections [001] to [016]: Zones 1 to 16, First Digit = 1
When the system is armed and a zone defined with Entry Delay 1 opens, the control panel will generate an
alarm after the programmed Entry Delay 1 Timer elapses. This is to provide users with enough time to
enter the protected area and disarm the system. To program the Entry Delay 1 Timer, key in the desired 3-
digit delay value (000 to 255 seconds, Default = 45 seconds) into section [069]. Entry Delay zones are
commonly used at the entry/exit points of the protected area (i.e. front/back door, garage, etc.). Using
different Entry Delays (see Entry Delay 2) is useful when, for example, one entry point requires a longer
delay than the other entry point or in a partitioned system where each partition may require a different
Entry Delay.
Press the
[
ENTER
key
Key in
3-digit [
SECTION
]
Zone Definition
First Digit
Zone Options
Feature Select
Enter the
[
INSTALLER
 
CODE
]
Zone Definitions
1 - Entry Delay 1
2 - Entry Delay 2
3 - Follow
   
     
4 - Instant
     
5 - 24Hr. Burglary
6 - 24Hr. Buzzer
Additional definitions for on-board
terminals:
7 - Keyswitch
8 - 24Hr. Fire
9 - 24Hr. Delayed Fire
Zone Options
[1] Auto Zone Shutdown Enabled
[2] Bypass Enabled
[3] Stay Zone
[4]     [5]    Zone Alarm Type
off     off    Audible Alarm (steady)
off     on    Audible Alarm (pulsed)
on     off    Silent Alarm
on     on    Generates only a report
[6] Intellizone
[7] Delay alarm transmission
[8] Force Zone
Keyswitch Options
[1]
off = Maintained
on = Momentary
[2]
off = Regular Arm
on = Stay Arm
Select
one
Press [
ENTER
]
[001] = Zone 1    [009] = Zone 09
[002] = Zone 2    [010] = Zone 10
[003] = Zone 3    [011] = Zone 11
[004] = Zone 4    [012] = Zone 12
[005] = Zone 5    [013] = Zone 13
[006] = Zone 6    [014] = Zone 14
[007] = Zone 7    [015] = Zone 15
[008] = Zone 8    [016] = Zone 16
Zone Partition
Assignment
Second Digit
Select
one
Zone Partition Assignment
1- Zone Assigned to Partition 1
2- Zone Assigned to Partition 2
3- Zone Assigned to Both Partitions
Keypads beep twice