Recognition ignores the bypass definition. This means the control panel will generate an incident as per
Tamper Recognition settings if a tamper or wire fault occurs on a bypassed zone. 
7.4
KEYPAD PANIC OPTIONS
Section [128]: General Options
Option [1] OFF = Emergency Panic Disabled (default)
Option [1] ON  = Emergency Panic Enabled
Pressing the [1] and [3] keys simultaneously on the keypad for 2 seconds will generate a silent or audible alarm as
defined by option [4].
Option [2] OFF = Auxiliary Panic Disabled (default)
Option [2] ON  = Auxiliary Panic Enabled
Pressing the [4] and [6] keys simultaneously on the keypad for 2 seconds will generate a silent or audible alarm as
defined by option [5].
Option [3] OFF = Fire Panic Disabled (default)
Option [3] ON  = Fire Panic Enabled
Pressing the [7] and [9] keys simultaneously on the keypad for 2 seconds will generate a silent or audible alarm as
defined by option [6].
Option [4] OFF = Emergency Panic is Silent (default)
Option [4] ON  = Emergency Panic is Audible
Option [5] OFF = Auxiliary Panic is Silent (default)
Option [5] ON  = Auxiliary Panic is Audible
Option [6] OFF = Fire Panic is Silent (default)
Option [6] ON  = Fire Panic is Pulsed
Silent alarm:
The control panel emits a Confirmation Beep and transmits the appropriate Panic report code if programmed in
section [195]. The control panel will not enable the keypad buzzers or the control panel’s 
BELL
 output (no audible
alarm). 
Audible alarm:
Same as silent alarm, except the keypad buzzers and the 
BELL
 output will activate until a user cancels the alarm
(disarms) with a valid User Access Code or when the Bell Cut-Off Timer elapses (see page 30).
Fire (pulsed) alarm:
Same as audible operation, except that the 
BELL
 output will be pulsed as shown in Figure 5.3 on page 23.
Whether the system is partitioned or not, the control panel will report all panic alarms to partition 1.
7.5
PANIC LOCKOUT TIMER
Section [094]
When a panic alarm is activated, the control panel can ignore the disarm signal from a remote control (see the SPC-
319 Wireless Bus Module Reference & Installation Manual) for a specified period. This prevents an aggressor from
disarming the system by remote control during a panic situation. In section [094] enter a 3-digit value (000 to 255,
000 = disabled) representing the number of seconds that the remote controls will be locked out of the system.