Spectralink 1728 Benutzerhandbuch

Seite von 64
S
PECTRA
 S
ERIES
 
  45
10.10 CONFIDENTIAL MODE
Section [126] Options [1], [2] and [3] 
Option [1] OFF = Confidential Mode Disabled (default)
Option [1] ON
= Confidential Mode Enabled 
Option [2] OFF = Keypads activate when an access code is entered 
Option [2] ON
= Keypads activate when a key is pressed (default)
Option [3] OFF = Confidential Mode Timer is 2 minutes 
Option [3] ON
= Confidential Mode Timer is 5 seconds (default)
If Confidential Mode is enabled and no actions are performed on the keypads for the time defined by the
Confidential Mode Timer, all the keypads’ LEDs will be off and LCD screens will show “Paradox Family” until either a
key is pressed or an access code is entered. When the system exits Confidential Mode, the keypads will display the
system’s status. Confidential Mode is activated by enabling option [1]. Option [2] regulates whether the keypads will
be activated at the touch of a key or only when an access code is entered. Option [3] determines the amount of time
without action before the system enters Confidential Mode (5 seconds or 2 minutes).
10.11 INSTALLER QUICK FUNCTIONS KEYS
After entering the Installer Code, you can press a key to perform specific actions as described below.
10.11.1 I
NSTALLER
 T
EST
 M
ODE
[
ENTER
] + [
INSTALLER
 
CODE
] + [
TBL
OR
 [
TRBL
]
The Installer Test Mode allows you to perform walk tests where the bell or siren will squawk and the
keypad will emit a Confirmation Beep to indicate opened zones. To enter this mode, simply enter the
Installer Code then press the [
TBL
or [
TRBL
] key. The keypad will emit a confirmation beep. To disable this
mode, press the [
TBL
] key again. The keypad will emit a Rejection Beep.
10.11.2 T
EST
 R
EPORT
[
ENTER
] + [
INSTALLER
 
CODE
] + [
MEM
Sends the Test Report report code programmed in section [211] to the central station (see Reporting and
Dialer settings 
on page 32). 
10.11.3 C
ALL
 W
IN
L
OAD
 S
OFTWARE
[
ENTER
] + [
INSTALLER
 
CODE
] + [
BYP
Refer to page 49.
10.11.4 C
ANCEL
 C
OMMUNICATION
 
[
ENTER
] + [
INSTALLER
 
CODE
] + [
STAY
Cancels all communication until the next reportable event.
10.11.5 A
NSWER
 W
IN
L
OAD
 S
OFTWARE
[
ENTER
] + [
INSTALLER
 
CODE
] + [
FORCE
Refer to page 49.
10.12 4-OUTPUT BUS MODULE SUPERVISION
Section [129]: General Options
Option [7] OFF = 4-Output Bus
 
Module Supervision Disabled (default)
Option [7] ON
= 4-Output Bus
 
Module Supervision Enabled 
By enabling this option, the control panel will supervise the 4-Output Bus
 
Module (APR3-PGM4) connected to the
Spectra bus. This means that whenever the 4-Output Bus
 
Module is disconnected or is not communicating with the
control panel, the control panel will attempt to transmit the Module Fault report code programmed in section [210]
and the Module Loss Failure will appear in the keypads’ Trouble Display (see page 50). 
Modules with the APR- prefix are compatible with Spectra (versions 2.0 and higher) and Digiplex. Modules
with the APR3- prefix are compatible with Spectra( versions 2.0 and higher), Digiplex and DigiplexNE.