Spectralink 1728 Benutzerhandbuch

Seite von 64
S
PECTRA
 S
ERIES
 
  51
12.2 PROGRAMMING ACCESS CODES
Access Codes are personal identification numbers that allow you to enter certain programming modes, arm or
disarm your system as well as activate or deactivate PGMs. The Spectra security system supports the following:
System Master Code arms or disarm partitions using any arming method and can create, modify or delete any User
Access Code. 
Only the System Master Code can modify or delete User Access Codes assigned to both partitions.
Master Code 1 is permanently assigned to partition 1 and can be used to create, modify or delete User Access
Codes
 that are assigned to partition 1. 
Master Code 2 is permanently assigned to partition 2 (except when partitioning is disabled, Master Code 2 will be
assigned to partition 1) and can be used to create, modify or delete User Access Codes that are assigned to the
same partition. 
45 User Access Codes (including 1 Duress code)   
[10]
Telephone Line Monitoring
If the Telephone Line Monitoring (TLM) feature is enabled (see section 
[135]), this trouble indicates that the control panel has not detected the 
presence of a telephone line for 30 seconds.
[
STAY
] or 
[11]
Fire Loop Trouble
Indicates a wiring problem on a Fire Zone. Press [
STAY
] to view the zones 
that are generating this trouble. 
[
FORCE
or [16]
Keypad Fault
If the keypad is no longer communicating with the control panel, the [
TBL
] 
or [
TRBL
will flash, the [
FORCE
key will illuminate (the LCD keypad 
displays “Keypad Fault”) and the keypad will emit four consecutive beeps 
at 5-second intervals. Press any key on the keypad to terminate the 
“beeping” sequence. When communication has been restored, the system 
will revert to previous status.
[
BYP
]
 
or [12]
Module Loss
A bus module is no longer communicating with the control panel. The 
module’s supervision option must be enabled [129].
[
MEM
]
or [13]
Wireless Transmitter 
Supervision Loss
One or more wireless transmitters are no longer communicating with the 
receiver. If you press the [
MEM
key, the keypad will display which zones 
are in trouble. 
How Do I Program Access Codes?
1) Press [
ENTER
]
2) Key in the [
SYSTEM
 
MASTER
 
CODE
or [
MASTER
 
CODE
3) Key in 3-digit [
SECTION
] (see Table below)
4) Key in new 4- or 6-digit [
ACCESS
 
CODE
]
[
ENTER
] flashes. Return to step 3
How Do I Delete Access Codes?
1) Repeat steps 1 to 3 (see above)
2) Press the [
FORCE
] key once for each digit in the access code (4 or 6 times) until the keypad emits a 
Confirmation Beep
Section
User Codes
[001]
User Code 001 = System Master Code
[002]
User Code 002 = Master Code 1
[003]
User Code 003 = Master Code 2
[004] to [047]
User Code 004 to User Code 047
[048]
User Code 048 or Duress Code
Table 10: Trouble List
LED #
Description
Details