IBM XSERIES 220 Benutzerhandbuch
![IBM](https://files.manualsbrain.com/attachments/f70d337d03c66895b7a6fbe0e6de3554f47d7dd3/common/fit/150/50/fb4e568062ca4d0154259807170f4c71f2c7aafa861a4d9a0eb3af958af4/brand_logo.png)
Symptom-to-FRU index
115
Diagnostic error codes
Note:
In the following error codes, if XXX is 000, 195, or 197do not replace a FRU.
The description for these error codes are:
The description for these error codes are:
000
The test passed.
195
The
Esc
key was pressed to abort the test.
197
This is a warning error and may not indicate a hardware failure.
For all error codes, replace/follow the FRU/Action indicated.
Error Code/Symptom
FRU/Action
001-XXX-000
(Failed
core tests)
1.
System Board
001-XXX-001
(Failed core
tests)
1.
System Board
001-250-000
(Failed
System Board ECC)
1.
System Board
001-250-001
(Failed
System Board ECC)
1.
System Board
005-XXX-000
(Failed
Video test)
1.
Video Adapter (if installed)
2.
System Board
011-XXX-000
(Failed
COM1 Serial Port test)
1.
System Board
011-XXX-001
(Failed COM2 Serial Port test)
(Failed COM2 Serial Port test)
1.
System Board
014-XXX-000
(Failed Parallel Port test)
(Failed Parallel Port test)
1.
System Board
015-XXX-001
(USB interface not found,
board damaged)
(USB interface not found,
board damaged)
1.
System Board
015-XXX-015
(Failed USB External
Loopback test)
(Failed USB External
Loopback test)
1.
Make sure parallel port is not disabled
2.
Re-run USB External Loopback test
3.
System Board
015-XXX-198
(USB device connected
during USB test)
(USB device connected
during USB test)
1.
Remove USB devices from USB1 and USB2
2.
Re-run test
3.
System Board
020-XXX-000
(Failed
PCI Interface test)
1.
System Board
030-XXX-000
(Failed
Internal SCSI interface test)
1.
System Board
030-XXX-00N
(Failed
SCSI test on PCI slot N.
Check system error log before
replacing a FRU.)
Check system error log before
replacing a FRU.)
1.
Adapter in Slot N
035-XXX-099
1.
No adapters were found.
2.
If adapter is installed re-check connection.