IBM XSERIES 220 Benutzerhandbuch

Seite von 178
 
 General information
 5
Keyboard port
Mouse port
IDE controller port
Video port
Acoustical noise emissions:
Sound power, idling: 5.9 bel maximum
Sound power, operating: 6.1 bel maximum
Environment:
Air temperature:
— Server on: 10º to 35º C (50.0º to 95.0º F). Altitude: 0 to 914 m (2998.7 ft) 
— Server on: 10º to 32º C (50.0º to 89.6º F).  Altitude: 914 m (2998.7 ft) to 2133 m 
(6998.0 ft)
— Server off: 10º to 43º C (50.0º to 109.4º F). Maximum altitude: 2133 m (6998.0 ft) 
Humidity:
— Server on: 8% to 80%
— Server off: 8% to 80%
Heat output:
Approximate heat output in British thermal units (Btu) per hour
Minimum configuration:  341 Btu (100 watts)
Maximum configuration: 1604 Btu (470 watts)
Electrical input:
Sine-wave input (50-60 Hz) required
Input voltage low range:
— Minimum: 100 V ac
— Maximum: 127 V ac 
Input voltage high range:
— Minimum: 200 V ac
— Maximum: 240 V ac
Input kilovolt-amperes (kVA), approximately:
— Minimum: 0.08 kVA
— Maximum: 0.52 kVA
Server features
The design of the server takes advantage of advancements in symmetric 
multiprocessing (SMP), data storage, and memory management.  The server 
combines: 
Impressive performance using an innovative approach to SMP 
The server supports up to two Pentium III microprocessors.  The server comes 
with one microprocessor installed; you can install an additional microprocessor to 
enhance performance and provide SMP capability.
Large system memory 
The memory bus in the server supports up to 4GB of system memory.  The 
memory controller provides error correcting code (ECC) support for up to four 
industry-standard PC133, 3.3 V, 168-pin, 8-byte, registered, synchronous-
dynamic-random access memory (SDRAM) dual inline memory modules 
(DIMMs).