Hardware Maintenance Manual: xSeries 220
 
 
2.
The Devices and I/O Ports choice appears only on the full Configuration/Setup 
Utility menu. If you have set both levels of passwords (user and administrator), 
you must type the administrator password to access the full Configuration/Setup 
Utility menu.
Parallel port
The server has one parallel port. This port supports three standard Institute of 
Electrical and Electronics Engineers (IEEE) 1284 modes of operation: Standard Parallel 
Port (SPP), Enhanced Parallel Port (EPP), and Extended Capability Port (ECP).
Viewing or changing the port assignments
You can use the Configuration/Setup Utility program to configure the parallel port as 
bidirectional; that is, so that data can be both read from and written to a device. In 
bidirectional mode, the server supports the ECP and EPP modes.
To view or change the parallel-port assignment, do the following: 
1.
Restart the server and watch the monitor screen. 
2.
When the message Press F1 for Configuration/Setup appears, press F1.
3.
From the main menu, select Devices and I/O Ports; then, press Enter.
4.
Select the parallel port; then, use the arrow keys to advance through the available 
settings.
Note:
When you configure the parallel port as bidirectional, use an IEEE 1284-
compliant cable. The maximum length of the cable must not exceed 3 
meters (9.8 feet).
5.
Select Save Settings; then, select Exit Setup to exit from the Configuration/Setup 
Utility main menu.