Intel SE8500 Benutzerhandbuch

Seite von 30
 
LAN Channel, Screen 3 – Alerts  
Alerts can be sent over the network from the NIC or via e-mail (system dependent). The 
information needed is configured on Screen 3. 
 
 
Figure 13.  LAN Screen 3 – Alerts 
•  Enable LAN Alerting : Must be checked for alerts to be sent.  
•  Alert Destination Console 1 IP Address 
•  Alert Destination Console 2 IP Address  
   
Enter the IP address of the preferred Console(s) to receive the alerts.  
•  Check the checkboxes to Resolve Destination MAC Addresses (earlier versions had the text 
Resolve Gateway) or Fill in the Destination MAC number
 
•  SNMP Community String:  Required field in the SNMP traps header. If not set, will default 
to “public”. Can be 5-18 characters in length.  
 
•  LAN Alert Filters button will bring up the next screen (see next section).   
 
The bottom 3 check boxes provide the option to replace LAN alerts with email alerts on systems 
with the Intel® Management Module – Advanced Edition. To do so, the IP address used by the 
SMTP service must be entered for either the first or second destination address.  
•  No Email (default when IMM - Professional Edition is installed) 
•  Send Email Alerts via LAN Alert IP Address 1 
•  Send Email Alerts via LAN Alert IP Address 
.  
17