Renesas HS6400FDIW3S Benutzerhandbuch

Seite von 146
 
111 
Chapter 12   E8 Update 
When connecting to an E8 interface adaptor board, FDT will check that the E8 firmware (adaptor software) 
is the correct version and correct type for supporting the connection to the selected device. If there is a 
mismatch then FDT will offer to update the E8 firmware in order that the connection can be continued. 
Also if the E8 Adaptor checksum is incorrect, an update will be required. Note that in some cases, an 
update to an earlier version number may be required if the current version does not support the selected 
device. It is very important that the E8 is not unplugged during the update process because this could result 
in the E8 being left in an erased state. 
NOTE - The E8 has two firmware areas, a ‘Level 0’ and a ‘Level 1’ (the Bootstub and Adaptor Software 
respectively). Typically FDT will only update the Level 1 area but in some cases a Level 0 update is also 
required. This is usually seen when connecting with E8Direct (see Chapter 13 - E8Direct) for the first time 
and will result in a slightly different update process, shown below for comparison: 
Level 0 and Level 1 update: 
E8 target power has been set to ON at 5.0V 
Connecting to device 'R5F21174' on 'E8' 
Configuration: 
'BOOT Mode' connection - using emulated interface 
Opening port 'E8' ... 
Checking for E8 update... 
Adaptor checksum OK 
Processing Data file :'c:\FDT\ADPFiles\E8-Rel-Img.mot' 
Mismatched Bootstub (Level 0) version number found (current E8 version = 
1.00.01.000, FDT holds version 2.00.00.000, FDT requires version 2.00.XX.XXX) 
 
 
 
Update selected 
Adaptor update started (do not unplug)... 
Processing Data file :'c:\FDT\ADPFiles\MonpMain.mot' 
  Adaptor update program downloaded... 
Processing Data file :'c:\FDT\ADPFiles\AdpErase0.mot' 
  Adaptor erased... 
Processing Data file :'c:\FDT\ADPFiles\AdpWrite0.mot' 
Updating... 
Adaptor updated successfully 
<Connection continues…>