2.3 
Connecting User System Interface Board to Evaluation Chip Board 
WARNING
 
   
Observe the precautions listed below.  Failure to do so  
  will result in a FIRE HAZARD and will damage the user  
  system and the emulator product or will result in  
  PERSONAL INJURY.  The USER PROGRAM will be  
  LOST.   
  1.   Always switch OFF the user system and the emulator 
   
product before the USER SYSTEM INTERFACE BOARD  
   
is connected to or removed from any part.  Before  
   
connecting, make sure that pin 1 on both sides are  
   
correctly aligned.  
  2.  The user system interface board dedicated to the  
   
emulator must be used.   
1.  Make sure that power of the user system and the emulator is turned off. 
2.  Align the connectors on the board with those on the evaluation chip board according to their 
numbers (figure 4). 
3.  Adjust the height of the spacer of the evaluation chip board with the user system.