Siemens M7-400 Benutzerhandbuch
Interface Submodules
13-18
S7-400, M7-400 Programmable Controllers Module Specifications
A5E00069467-07
13.5.2
Addressing and Interrupts
Addressing
The IF 962-LPT interface submodule can be addressed in the following two ways:
•
In the AT-compatible I/O address area
•
In the M7-300/400-reserved I/O address area (from C000
H
)
Addressing in the AT-Compatible I/O Address Area
The LPT ports can be operated in the AT-compatible I/O address area. The
settings are made in the BIOS Setup. You can see the addresses that can be set in
the BIOS Setup from the following table.
settings are made in the BIOS Setup. You can see the addresses that can be set in
the BIOS Setup from the following table.
Table 13-16
Addressing the LPT Ports
Name
I/O Address
Remarks
03BC
H
to 3BE
H
*)
0378
H
to 37F
H
Automatically configured by the BIOS and
can be set in the BIOS setup
can be set in the BIOS setup
)
0278
H
to 27F
H
can be set in the BIOS setup.
*) The BIOS searches the addresses in the order 03BC
H
, 0378
H
and 0278
H
and assigns
LPT1, LPT2 and LPT3 in ascending order. There is no fixed assignment of the I/O
addresses to LPTx. For example, if only one LPT port is detected at address 0378
addresses to LPTx. For example, if only one LPT port is detected at address 0378
H
, this
will be LPT1.
Note
The LPT port in the M7-400 expansion module MSM 478 is always at the I/O
address 03BC
address 03BC
H
. For this reason, the I/O address 03BC
H
must not be set for the IP
962-LPT interface submodule if an MSM 478 is in use.