Dialogic D/41JCT-LS-EW Merkblatt

Seite von 2
If the D/41JCT-LS-EW or VFX/41JCT-LS-EW will be 
connected to other telephony boards via a CT Bus 
cable, you should install the boards to minimize 
unused connectors on the CT Bus cable:
Install boards in adjacent slots whenever 
possible.
If the D/41JCT-LS-EW or VFX/41JCT-LS-EW 
board will be connected to one or more PCI 
boards, use the PCI Express slot(s) closest to the 
PCI slots.
5. Installing the Board
WARNING! Unplug the equipment before 
performing the procedures described here. 
Failure to disconnect the power before you 
open the chassis can result in personal injury. 
Ensure that the system is disconnected from 
its power source and from all 
telecommunications links, networks, or 
modem lines whenever the chassis cover is 
removed. Do not operate the system with the 
cover removed.
CAUTION: To avoid possible damage to the board, 
remove power from the computer before beginning 
installation. Observe proper anti-static precautions 
at all times while handling and installing the board.
To install a D/41JCT-LS-EW or VFX/41JCT-LS-EW 
board, perform the following steps:
1. Turn off all power to the system and disconnect 
the system’s power cords.
2. Remove the computer’s cover.
3. Choose an empty PCI Express expansion slot 
and remove the slot’s retaining screw and 
access cover plate.
Note: If you are not installing the board in 
a full-length form-factor PCI Express slot, 
remove the slot retainer bracket from the 
end of the board before installation.
4. Insert the board’s edge connector into the bus 
slot, and apply firm pressure to the top edge of 
the board until the board is fully seated in the 
edge connector.
5. Reinstall the retaining screw.
6. Repeat steps 1 through 5 for any additional 
boards you are installing.
7. If applicable, connect the telephony boards 
together with a CT Bus cable of the appropriate 
size (not included). If possible, use a cable 
assembly that matches the number of boards in 
your system. If the cable has more than one 
unused connector, install the cable so that all 
the unused connectors are at one end of the 
cable.
8. Replace the computer’s cover.
9. Reconnect the computer’s power cord.
PCI Slots
PCI Express
Slots
PCI Express
Board
Computer
Chassis
Remove
Cover
Plate
Note:
Your CT Bus cable may 
have a different number of 
connectors (drops). 
CT Bus
Cable
Colored
Stripe
(Pin 1)
6. Connecting to External 
Equipment
Each RJ-11 jack on the rear bracket of the 
D/41JCT-LS-EW and VFX/41JCT-LS-EW boards 
supports a single channel. Use RJ-11 connectors 
and telephone cable to connect each channel to an 
analog PBX or standard telephone outlet.
Note: Since these boards emulate a standard 
telephone, a standard telephone will not function 
when directly connected to the board.
Note: Connect the Earth Recall signal to pin 2. Do 
not connect Tip or Ring lines to pin 2, or improper 
operation of the D/41JCT-LS-EW or VFX/41JCT-LS-
EW will result.
7. After Installing the Board
The D/41JCT-LS-EW and VFX/41JCT-LS-EW boards 
require the use of an Dialogic
®
 System Software 
version that specifically supports it.
1
If this is the first Dialogic
®
 telecom board you have 
installed in your system, you will need to install an 
appropriate version of the Dialogic
®
 System 
Software and configure the software for the specific 
board(s) you are using. Refer to the installation 
and configuration documentation that accompanies 
the release for instructions.
1.Required Dialogic
®
 System Software:
System Release 6.0 PCI for Windows Ser-
vice Update 131 or higher; System Release
6.1 for Linux Service Update 232 or higher.
Channel 1
Channel 2
Channel 3
Channel 4
To analog 
PBX 
or 
standard 
telephone 
outlet
Rear 
bracket 
on board
1
2
3
4
Pin
5
6
2
5
4
3
6
1
J1-J4 on the D/41JCT-LS 
and VFX/41JCT-LS Board
RJ-11 Connector
Signal
Unused
Station - Earth Recall
Unused
Station - Ring
Station - Tip
Unused
If you are installing the board in a system that 
already has the Dialogic
®
 System Software 
installed, you should verify that your installed 
software version supports the board. If not, you 
will need to obtain and install a Service Update that 
does support the D/41JCT-LS-EW and VFX/41JCT-
LS-EW boards before configuring the system for 
the newly installed board(s).
Please refer to the Release Update document for 
your release version (on the Dialogic Telecom 
Support Resources web page) for up-to-date 
information about support for PCI Express boards 
and any known issues relating to their use.
8. Removing the Board
Removal of the D/41JCT-LS-EW and VFX/41JCT-LS-
EW board is essentially the reverse of the 
installation procedure:
1. Observe anti-static precautions.
2. Disconnect the telephony cables.
3. Remove the computer’s power cord.
4. Remove the computer’s cover.
5. Disconnect the CT Bus cable (if applicable).
6. Remove and set aside the board’s retaining 
screw.
7. Remove the board and place it in static-
protective packaging.
9. Warranty and Return 
Information
For specific warranty information for this 
board, refer to the Warranty section of the 
Products page, located at this URL: http://
www.dialogic.com/warranties/. 
Contacting Technical Support
Dialogic provides technical support for its 
products through a network of value added 
distributors who are trained to answer 
technical questions on installing and 
configuring Dialogic® products. If you are 
unsure how to contact your support channel, 
please call Dialogic in the United States at 
973-967-6600 (9am-5pm EST) and we will 
assist in obtaining the appropriate support 
channel. Outside the United States please 
refer to http://www.dialogic.com/support/
contact to obtain local contact information. 
Dialogic also provides direct support via 
Dialogic
®
 Pro™ Services agreements. For 
more details of direct support from Dialogic 
please refer to:http://www.dialogic.com/
support/DialogicPro
Returning a Product
To return a board for warranty repair or any 
other returns, please refer to the following: 
http://www.dialogic.com/support/hwfaults.
10.Sales Assistance
If you have a sales question, please contact 
your local Sales Representative or the 
Regional Sales Office for your area. Address, 
telephone and fax numbers, are available at 
the Dialogic website located at: http://
www.dialogic.com/contact.htm.
To purchase Dialogic® products, please refer 
to the following website to locate the 
appropriate supplier: http://
www.dialogic.com/purchase.htm.
All contents of this document are furnished for informational use only and 
are subject to change without notice and do not represent a commitment 
on the part of Dialogic Corporation or its subsidiaries (“Dialogic”). 
Reasonable effort is made to ensure the accuracy of the information 
contained in the document. However, Dialogic does not warrant the 
accuracy of this information and cannot accept responsibility for errors, 
inaccuracies or omissions that may be contained in this document.
INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH 
DIALOGIC® PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY 
ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS 
GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN A SIGNED 
AGREEMENT BETWEEN YOU AND DIALOGIC, DIALOGIC ASSUMES NO 
LIABILITY WHATSOEVER, AND DIALOGIC DISCLAIMS ANY EXPRESS OR 
IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF DIALOGIC 
PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO 
FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR 
INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT OF A THIRD 
PARTY.
Dialogic products are not intended for use in medical, life saving, life 
sustaining, critical control or safety systems, or in nuclear facility 
applications.
It is possible that the use or implementation of any one of the concepts, 
applications, or ideas described in this document, in marketing collateral 
produced by or on web pages maintained by Dialogic may infringe one or 
more patents or other intellectual property rights owned by third parties. 
Dialogic does not provide any intellectual property licenses with the sale of 
Dialogic products other than a license to use such product in accordance 
with intellectual property owned or validly licensed by Dialogic and no such 
licenses are provided except pursuant to a signed agreement with Dialogic. 
More detailed information about such intellectual property is available from 
Dialogic’s legal department at 9800 Cavendish Blvd., 5th Floor, Montreal, 
Quebec, Canada H4M 2V9. Dialogic encourages all users of its 
products to procure all necessary intellectual property licenses 
required to implement any concepts or applications and does not 
condone or encourage any intellectual property infringement and 
disclaims any responsibility related thereto. These intellectual 
property licenses may differ from country to country and it is the 
responsibility of those who develop the concepts or applications to 
be aware of and comply with different national license 
requirements. 
Dialogic, Diva, Eicon, Eicon Networks, Eiconcard, Dialogic Pro and 
SIPcontrol, among others, are either registered trademarks or trademarks 
of Dialogic. Dialogic's trademarks may be used publicly only with 
permission from Dialogic. Such permission may only be granted by 
Dialogic’s legal department at 9800 Cavendish Blvd., 5th Floor, Montreal, 
Quebec, Canada H4M 2V9. Any authorized use of Dialogic's trademarks will 
be subject to full respect of the trademark guidelines published by Dialogic 
from time to time and any use of Dialogic’s trademarks requires proper 
acknowledgement. The names of actual companies and products 
mentioned herein are the trademarks of their respective owners