Input Sample Rate
For PCM input modes, the input sample rate can be sensed and set
automatically, using the 
Auto
 option, or forced. The latter is useful where use of
1 or 2 wire mode for higher sample rates might be ambiguous – otherwise 
Auto
is best.  It occurs at the bottom of the 
Input Sample Rate
 list:
Select the required entry from the list and press 
Set
. If you have selected 
Auto
,
then the list changes when re-entered:
and the 
Status
 display will indicate that 
Auto
 is on:
Output Sample Rate
Output Sample Rate
 is a parameter for PCM output modes only. Select the
required 
Output Sample Rate
 from the list and press 
Set
. The dCS 974
accepts 112 input / output sample rate combinations (including DSD) in one
pass. The remaining 70 combinations can be accommodated in 2 passes.
These are shown in 
 overleaf.
Not all the apparently valid output sample rates may be available to you from
the menu. When 
Auto
  Input Sample Rate Selection is turned on, the menu
system dynamically alters the 
Output Sample Rate
 menu to reflect the valid
1 pass output rates for the current input rate. For example, if 
Auto 
is turned on
and the input is running at 96 kS/s, then the 
Output Sample Rate
 menu would
look like this: