Fujitsu FR81S Benutzerhandbuch
CHAPTER 40: MULTI-FUNCTION SERIAL INTERFACE
7. Operation of LIN Interface (v2.1)
FUJITSU SEMICONDUCTOR LIMITED
CHAPTER : MULTI-FUNCTION SERIAL INTERFACE
FUJITSU SEMICONDUCTOR CONFIDENTIAL
312
7.6. Setup Procedure and Program Flow
Setup procedure and program is shown.
In operation mode 3 (LIN communication mode), the selected baud rate can be used for the LIN master
system or LIN slave system.
CPU Interconnection
The following Figure shows a communication system that contains one LIN master and one LIN slave. The
multi-function serial interface can work as a LIN master or LIN slave.
Figure 7-70 Example of LIN Bus System Communication
LIN Master
LIN Slave
SOT
SIN
SIN
SOT
SIN
SIN
Transceiver
Transceiver
MB91520 Series
MN705-00010-1v0-E
1625