Emerson ATCA-9305 Benutzerhandbuch

Seite von 184
Management Processor Monitor:
 Command-Line Features
9-2
Figure 9-1:
Example MPC8548 Monitor Start-up Display 
This prompt is also displayed as an indication that the monitor has finished executing a 
command or function invoked at the command prompt (except when the command loads 
and jumps to a user application). The hardware product name (ATCA-9305), and current 
software version number are displayed in the prompt. 
Prior to the console port being available, the monitor will display a four-bit hexadecimal 
value on LED1 through LED4 to indicate the power-up status (see 
). See 
 fo
the debug LED locations. In the event of a specific initialization error, the LED pattern will be 
displayed and the board initialization will halt.
Table 9-1:
Debug LED Codes 
LED Code:
Power-up Status:
LED Value:
BOARD_PRE_INIT
start booting, setup BATs done
0x01
SERIAL_INIT
console init done
0x02
Hardware initialization
Monitor command prompt
U-Boot 1.1.4 (Jan  8 2007 - 16:07:48)1.0
CPU:   8548_E, Version: 2.0, (0x80390020)
Core:  E500, Version: 2.0, (0x80210020)
Clock Configuration:
       CPU: 999 MHz, CCB: 399 MHz,
       DDR: 199 MHz, LBC:  49 MHz
Board: ATCA-9305 ATCA Blade
       Emerson Network Power, Embedded Computing Inc.
       cPLD Ver: 2
I2C:   ready
Clearing ALL of memory
................
DRAM:  512 MB
Testing Top 1M Area of DRAM........PASSED
Relocating code to RAM
FLASH: [4MB@e0000000][4MB@e1000000]8 MB
L2 cache:  enabled
In:    serial
Out:   serial
Err:   serial
Ser#:  1096
Diags Mem:             PASSED
Diags I2C:             PASSED
Diags Flash:           PASSED
BootDev:  Socket
I-cache enabled
D-cache enabled (write-through)
L2 cache enabled. (L2CTL: 0xa0000000)
 (write-through)
IPMC:  v0.1.1
DOC:   Turbo Mode
Net:   eTSEC1, eTSEC2
ATCA-9305 (Mon 1.0)=>