Safety Notes
MITX-430/MITX-440-DVI-2E Installation and Use Guide (6806800K37B)
111
 
As soon as you modify the product or change the default configuration you are responsible for 
complying with all relevant regulatory standards.
VCCI
 
This is a Class B product based on the standard of the Voluntary Control Council for 
Interference by Information Technology Interference (VCCI). If this equipment is used in a 
domestic environment, radio disturbance can arise. When such trouble occurs, the user is 
required to take corrective actions.
Installation
 
Damage of Circuits
Electrostatic discharge and incorrect installation and removal of the product can damage 
circuits or shorten their life.
Before touching the product make sure that your are working in an ESD-safe environment or 
wear an ESD wrist strap or ESD shoes. Hold the product by its edges and do not touch any 
components or circuits.
 System 
Damage
To avoid system damage verify that the system environment meets the 
environmental and power requirements given in this manual before installing the 
system.
Before you begin to set up and cable your new system, consider these guidelines:
z
Restricted access area: Install the system only in a restricted access area.
z
Installation codes: This unit must be installed in accordance with the National Electrical 
Code, Articles 11016, 11017, and 11018 and the Canadian Electrical Code, Section 12.
z
Overcurrent protection: A readily accessible listed branch circuit overcurrent protective 
device must be incorporated into the building wiring. For appropriate AWG rating of the 
overcurrent protection device see NEC Table 31016 and other national regulations.
z
The protective bonding conductor depends on your power distribution topology. Make 
sure that you use an appropriate protective bonding conductor regarding the rating of the 
branch circuit protection.