Gateway ALR 9200 Benutzerhandbuch

Seite von 226
142     Maintaining and Troubleshooting the Gateway ALR 9200 Server
SEL Viewer Menu Options
The following menu options are available on the SEL viewer menu bar:
File 
Open: Allows you to view SEL data from a previously saved 
file if it was stored in binary format. Selecting the Open Menu 
item lets you specify a filename under which the data are 
found. The default filename is “SELLOG.DAT.”  If the file 
cannot be opened, the program displays an error message.
Close: Closes the SEL viewer.
Save As: Dumps the SEL data to a file in either binary or text 
format. The binary file can be retrieved later. This option lets 
you specify a filename to which the data is saved. The default 
filename is “SELLOG.DAT.” If no data exist, the system 
displays an error message.
Exit: Exits the EMP console.
Connect
View
SEL Information: Displays SEL summary information.
All Events: Displays all events in the SEL.
By Sensor Type: Displays all events in the SEL generated by 
a specific sensor type, e.g., voltage, temperature, etc.
By Event: Displays all events in the SEL of a particular type, 
for example, by memory or threshold. A pop-up menu lets you 
select the event type to display. This menu displays all event 
types that can be generated by the hardware.
Settings: Lets you change several operating parameters for the 
SEL viewer. This menu displays the following suboptions:
Display HEX/Verbose: Toggles between HEX mode and 
interpreted mode of displaying SEL records.
Output Text/Binary: Specifies whether SEL data is saved to 
the file in binary format or verbose format.
Window: Gives options for displaying currently open windows.
Help: Provides version information for the SEL viewer and 
provides help topics on the EMP console.
3424.boo  Page 142  Wednesday, September 2, 1998  9:23 AM