Acu-Rite CNC 3500i Benutzerhandbuch

Seite von 472
ACU-RITE 3500i
407
1
1
.4 A
d
v
a
nced Pr
ogr
a
mming
User Macros (G65, G66, G67)
Use G66 when you want to use a modal macro sub-program. These 
groups of instructions can be special canned cycles made up by the 
user to simplify the programming of the particular part, or master 
programs for similar part families, programmed with variables rather 
than fixed dimensions. 
Macros can contain automatic measuring sequences for sensors, 
such as a probe, for feedback to the 3500i. 
Format #
Function
G65 Pn Ln
Non-modal macro call. Call macro n. Execute 
macro, at the current position, only once. The 
sub-program can be looped (L).
G66 Pn
Modal macro call. Call macro n. Execute macro 
at any X and/or Y location given after the G66 
code, until G67 (cancel) is called. G66 stays 
active until G67 is called.
G67
Cancel Modal Macro Call (G66).