SATO ct4i Benutzerhandbuch

Seite von 74
Unit 2:  Technical Data
CT4i Series Operator Manual
2-8
 
IEEE1284 PARALLEL INTERFACE
The parallel interface is a plug-in module that can be installed by the user and conforms to  IEEE1284
specifications. It automatically detects the IEEE1284 signals and operates in the high speed mode. If the
IEEE1284 signals are not detected, it will operate in the slower standard Centronics mode. For this reason, an
interface cable and host interface conforming to the IEEE1284 specification must be present to fully utilize the
speed capabilities. This interface also operates bi-directionally and can report the status of the printer back to the
host.
Figure 3-6, Parallel Connector Pin Assignments
SPECIFICATIONS
Printer Connector
AMP 57-40360 DDK (or equivalent) 
Cable Connector
AMP 57-30360 DDK (or equivalent)
Cable
4.9 ft. (1.5 meter) or less
Signal Level
High = +2.4V to +5.0V, Low = 0V to -0.4V
Data Stream
<ESC>A . . Job#1 . . <ESC>Z<ESC>A . . Job#n . . <ESC>Z
PIN ASSIGNMENTS
PIN
SIGNAL
DIRECTION
PIN
SIGNAL
DIRECTION
1
Strobe
To Printer
19
Strobe Return
Reference
2
Data 1
To Printer
20
Data 1 Return
Reference
3
Data 2
To Printer
21
Data 2 Return
Reference
4
Data 3
To Printer
22
Data 3 Return
Reference
5
Data 4
To Printer
23
Data 4 Return
Reference
6
Data 5
To Printer
24
Data 5 Return
Reference
7
Data 6
To Printer
25
Data 6 Return
Reference
8
Data 7
To Printer
26
Data 7 Return
Reference
9
Data 8
To Printer
27
Data 8 Return
Reference
10
ACK
To Host
28
ACK Return
Reference
11
Busy
To Host
29
Busy Return
Reference
12
Ptr Error
To Host
30
PE Return
Reference
13
Select
To Host
31
INIT
From Host
14
AutoFD
1
To Host
32
Fault
To Host
15
Not Used
33
Not Used
16
Logic Gnd
34
Not Used
17
FG
Frame Gnd
35
Not Used
18
+5V (z=24k ohm)
To Host
36
SelectIn
1
From Host
Signals required for IEEE 1284 mode.