Multitech MT5600ZDX Benutzerhandbuch

Seite von 98
36
Models MT5600ZDX & ZDXV
Command: DS=n Dial Stored Telephone Number
Values:
n = 0–3
Default:
none
Description:
Dial a number previously stored in directory
number n by the &Zn=x command .
Example: ATDS=3
Command: En
Echo Command Mode Characters
Values:
n = 0 or 1
Default:
1
Description: E0
Do not echo keyboard characters to the computer.
E1
Do echo keyboard characters to the computer.
Command: Hn
On-Hook/Off-Hook Control
Values:
n = 0 or 1
Default:
0
Description: H0
Go on-hook to hang up.
H1
Go off-hook to make the phone line busy.
Command: In
Information Request
Values:
n = 0–7
Default:
None
Description: I0
Display product code.  Example: 33600
I1
Calculate and display ROM checksum (e.g., “12AB”).
I2
Calculates the ROM checksum and compares it to the
prestored checksum, displaying OK or ERROR.
I3
Display the firmware version and application codes.
I4
Display OEM defined identifier string in either binary
or ASCII format.
I5
Display country code (e.g., “NA Ver. 1”).
I6
Display modem data pump model and internal code
version.
I7
Display the DAA code resulting from MCU interroga-
tion of the DAA for auto DAA recognition.  Examples:
000 for US or Canada, 016 for Japan, 033 for
Belgium, 034 for Finland, 035 for France, 037 for
Italy, 038 for Netherlands, 039 for Sweden, 040 for
Switzerland, and 041 for UK.