Multi Tech Equipment ISIHI-2S Benutzerhandbuch

Seite von 186
MultiModemISI Hybrid Series, ISIHI-2S
131
Appendix
This step allows selection of a baud rate for testing. Once a baud rate is selected,  the
following displays:
ISI Terminal Utility is ready. Press F10 to Exit.
This message indicates that keyboard entry can now be performed. Any characters typed
on the keyboard are sent through the MutiModemISI board to the modem and then
returned to display on the PC screen. When operation is verified, exit the utility by
pressing F10.
2. Operation with setting other than factory defaults
The 608TERM.EXE program is a utility program that emulates a terminal to test the
connection from PC keyboard to ISI board to modem to ISI board to PC display. Prior to
executing 608TERM, the program must be executed to initialize the ISI board.
Enter 608TERM  -h <cr> to display the 608TERM program requirements. The following
displays:
A:\>608TERM -h
Usage is:
ISIterm
-1<2 to 7, 10 to 12 and 15> for specifying IRQ level.
-A<address> for specifying base address.
-H this help screen.
Note: This program must be run anytime the PC is powered down or rebooted.
Whenever the base IO address and/or the IRQ values have been changed, a parameter
string must be added to the command line. The string takes the form of [-Axxxx], where
xxxx represents the new base IO address value and [-Iy] and  y represents the IRQ value
selected. Three potential combinations exist for the formatting of the command line:
1. Changing only the base IO address setting, the command line takes the form:
608TERM [-Axxxx]
2. Changing only the IRQ setting, the command line takes the form: 608TERM [-Iy]
3. Changing both the base IO address and the IRQ settings, the command line takes
the form: 608TERM [-Axxxx] [-Iy]