SEAL 600-C Benutzerhandbuch

Seite von 32
 
 
9
S A F E T Y   F E A T U R E S  
The SEAL
®
 Image
®
 600-C Laminator is designed with 
safety and protective devices with the user’s safety of 
utmost consideration. However, following safe 
operating guidelines is still the responsibility of the 
operator. 
 
 
H
AND
-O
PERATED 
E
MERGENCY 
S
TOP 
B
UTTONS
Emergency Stop buttons are located on the top of each 
of the cabinets for easy access. Once pressed, they 
immediately cease the laminator’s operation and raise 
the top roller. Use these only in the case of an 
emergency or you may damage an image during a 
process.  
NOTE: Once pressed, these buttons lock and must 
be turned clockwise to reset.  
After resetting the Emergency Stop button, you must 
turn the main power back ON, and press the Motor 
Switch ON to begin processing again.  
 
 
C
OVERED 
F
OOT 
S
WITCH
The foot switch allows for complete user control when 
initially feeding an image into the nip or for feeding a 
delicate image through the rollers. The cover prevents 
accidentally stepping on the foot switch and starting the 
laminator.  
WARNING! On Domestic version laminators the 
foot switch overrides the photoelectric eyes. When 
the photo eye is blocked, a BUZZER sounds, 
warning of close proximity to the nip. Use care to 
keep hands clear of the rollers while using the foot 
switch to prevent possible injury.  
P
HOTO 
E
LECTRIC 
S
AFETY 
E
YES
A light beam path set directly in front of the laminating 
roller opening prevents foreign objects from passing 
between the rollers. (The eyes are set for use at the 
factory and checked by the service representative.) 
 
 
L
OCKING 
C
ABINETS
The cabinets that house the inner workings of the 
laminator include locks that maintenance or safety 
personnel can open only with the supplied keys. 
WARNING! Use of the inside of the cabinets for 
storage may cause possible personal injury and/or 
damage to the inner workings and will void the 
warranty. 
 
 
D
OOR 
I
NTERLOCK
 
Located on the left side cabinet (facing front of 
laminator), it automatically shuts the laminator power 
off when the door interlock switch is turned to the OFF 
position. 
WARNING! For any servicing, ALWAYS turn the 
door interlock switch to the OFF position and the 
main power circuit breaker off before opening the 
side cabinets.