Texas Instruments 51X Benutzerhandbuch

Seite von 85
A
Self Test Error Messages
A.1
 Introduction
This appendix contains reference data useful in diagnosing and correcting
self test errors.
Table A-1  Self Test Error Messages
Error Message 
Corrective Action
CMOS Battery Bad
Replace Main Board
CMOS Checksum Error
Cycle power to Notebook; if
problem persists, remove and re-
place Main Board.
Disk Boot Failure
Insert a system disk in drive A
Diskette Drive Controller Error or No
Controller Present
Cycle power to Notebook; if
problem persists
Diskette Drive Error
Insert Diskette and retry; if
problem persists, try another 
diskette
Diskette Drive Type Mismatch
Press Ctrl-Alt-Esc to reconfigure
the system.
Equipment Configuration Error
Press Ctrl-Alt-Esc to reconfigure
the system.
Hard Disk 0 Error
Cycle power to Notebook; if
problem persists, replace Hard
Drive
Hard Disk 0 Extended Type Error
Cycle power to Notebook; if
problem persists, replace Hard
Drive
Insert system diskette and press key 
to reboot
Insert a system disk in drive A
I/O Parity Error
Cycle power to Notebook; if
problem persists, replace Main
Board
Keyboard Error or No Keyboard 
Connected
Cycle power to Notebook; if
problem persists, check keyboard
connections; if problem persists,
replace Keyboard; if problem 
persists, replace Main Board.
Error  Messages  A-1