ATTO Technology SC 5700 Benutzerhandbuch

Seite von 73
xvii
 
ATTO Technology Inc. FastStream SC Installation and Operation Manual
SESDiskFailureAlarm 
SC 5500, SC 5700
Activates an audible alarm when the appliance determines that 
a RAID member disk drive has failed. The enclosure which 
contains the failed disk drive creates the sound, other 
enclosures are unaffected.
Default: disabled
set SESDiskFailureAlarm [enabled | disabled]
get SESDiskFailureAlarm
SESEnclosures
SC 5500, SC 5700
List SES-enabled enclosures which have been discovered by 
the appliance.
SESEnclosures
SESIdentify
SC 5500, SC 5700
Tells the appropriate SES enclosure to identify the specified 
element(s). ALL identifies all disks. RAID GroupName identifies 
all disks in a RAID Group. If the MemberIndex is also specified, 
only that disk is identified. ENC and enclosure index identifies 
all slots in the specified enclosure. DRIVE BlockDevID identifies 
the specified disk. 
Note
The SESEnclosures command must be 
executed before executing the SESIdentify 
ENC or SESIdentify ALL command.
set SESIdentify [ALL | RAID GroupName 
<MemberIndex> | ENC EnclosureIndex | DRIVE 
BlockDevID]
get SESIdentify [ALL | RAID GroupName 
<MemberIndex> | ENC EnclosureIndex | DRIVE 
BlockDevID]
SESIdentifyStop
SC 5500, SC 5700
Tells the appropriate SES enclosure(s) to stop identifying the 
specified element(s). If the MemberIndex is specified, only that 
disk is identified. DRIVE and BlockDevID identify the specified 
disk. 
SESIdentifyStop [ALL |GroupName <MemberIndex> | 
DRIVE BlockDevID]
SESMute
SC 5500, SC 5700
Causes the audible alarms for all known enclosures to be muted 
or to use the remind state. The remind state causes an 
occasional audible reminder, if supported by the hardware, of 
the alarm condition.
Note
The command SESEnclosures must be 
executed before executing SESMute.
Default: Mute
SESMute <EnclosureIndex> <remind>
SESPoll
SC 5500, SC 5700
Specifies the SES enclosure polling interval in seconds. At the 
specified interval, all known SES enclosures are polled for their 
current status. A setting of 0 disables SES enclosure polling.
Default: 60
set SESPoll [0 | 30-3600]
get SESPoll
SESStartingSlot
SC 5500, SC 5700
Establishes the starting slot/ID number for all attached SES 
enclosures.
Default: 1
set SESStartingSlot [ 0 | 1]
get SESStartingSlot
SESStatus
SC 5500, SC 5700
Displays the last polled status of the specified element type in 
the specified enclosure. Supported SES features include: fan, 
power, temperature, alarm and drive LEDs. If no element type 
is specified, the status of each is displayed.
Note
The command SESEnclosures must be 
executed before executing SESStatus.
SESStatus [EnclosureIndex] <ENC | DRIVES | FAN | 
POWER | TEMP | ALARM | SUPPORTLEVEL>
SNTP
Controls whether an SNTP time server sets the date and time.
Default: enabled
set SNTP [enabled | disabled] 
SaveConfiguration Restart command required
get SNTP
SNTPServer
Controls or displays the main IP address the client uses to 
retrieve the SNTP time and date.
Default: 192.43.244.18
set SNTPServer [xxx.xxx.xxx.xxx]
SaveConfiguration Restart command required
get SNTPServer